您的位置:首页 > 论文页面
生物接触氧化-复合垂直流人工湿地处理某制药废水的调试
发表时间:2010-12-31 浏览量:2083 下载量:776
全部作者: | 唐光涛,徐栋,贺锋,夏世斌,吴振斌 |
作者单位: | 中国科学院水生生物研究所淡水生态与生物技术国家重点实验室;武汉理工大学资源与环境工程学院 |
摘 要: | 针对某药业公司的制药废水水质情况,采用厌氧水解酸化与生物接触氧化强化预处理并联合复合垂直流人工湿地(integrated vertical-flow constructed wetland, IVCW)的处理工艺,将生物与生态技术耦合处理该类难降解污水。从调试准备、污泥培养、单元优化等方面探讨了调试过程中应注意的事项。调试运行及水质监测表明:该制药废水经过生物接触氧化法-复合垂直流人工湿地工艺净化出水化学需氧量(chemical oxygen demand, COD)达到污水综合排放标准(GB 8978-1996)第二类污染物一级排放标准。 |
关 键 词: | 水污染防治工程生物接触氧化;复合垂直流人工湿地;制药废水;调试 |
Title: | Debugging of pharmaceutical wastewater treatment by biological contact oxidation-IVCW process |
Author: | TANG Guangtao, XU Dong, HE Feng, XIA Shibing, WU Zhenbin |
Organization: | State Key Laboratory of Freshwater Ecology & Biotechnology; Institute of Hydrobiology; Chinese Academy of Sciences; Institute of Resource and Environment Engineering; Wuhan University of Technology |
Abstract: | According to the water quality, the waste water of a pharmaceutical company was treated by anaerobic hydrolysis-acidification and biological contact oxidation as enhanced pre-treatment, and integrated vertical-flow constructed wetland (IVCW) process as advanced treatment. In the combined process, bio-technology and eco-technology were well integrated. The matters which should be paid attention to were discussed from the aspects of debugging preparation, activated sludge culture and unit optimization. The debugging operation and water quality monitoring indicate that chemical oxygen demand (COD) in the effluent successfully meet integrated wastewater discharge standard (GB 8978-1996), classified as the second category of pollutants of wastewater discharge A standards, after the process of biological contact oxidation and IVCW. |
Key words: | water pollution control engineering biological contact oxidation; integrated vertical-flow constructed wetland; Pharmaceutical wastewater; debugging |
发表期数: | 2010年12月第24期 |
引用格式: | 唐光涛,徐栋,贺锋,等. 生物接触氧化-复合垂直流人工湿地处理某制药废水的调试[J]. 中国科技论文在线精品论文,2010,3(24):2500-2505. |